Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: netbudy65

RCDD-002 BICSI Registered Communications Distribution Designer - RCDD Questions and Answers

Questions 4

The concept of the "security quandary" is based on providing a balancing act between what two elements?

Options:

A.

Access and isolation

B.

Risk and threat

C.

Asset and isolation

D.

Asset and risk

E.

Access and cost

Buy Now
Questions 5

A security program consists of three independent components. They are electronic, architectural, and:

Options:

A.

Operational

B.

Physical

C.

Environmental

D.

Elemental

Buy Now
Questions 6

For an analog camera, what is the normal frame rate in frames per second?

Options:

A.

18 fps

B.

22 fps

C.

27 fps

D.

30 fps

E.

33 fps

Buy Now
Questions 7

In addition to voice and data services, an equipment room (ER) can be designed to include all of the following EXCEPT:

Options:

A.

CATV and CCTV facilities

B.

Life safety facilities

C.

Building electrical service monitoring and controls

D.

Audio and paging equipment

E.

General premise monitoring and security systems

Buy Now
Questions 8

On a survey of one of your client's buildings, you discover that one of the TRs, housing a considerable quantity of switching equipment, is at 25 degrees C (77 degrees F) with a relative humidity of 59 percent. This is considered to be:

Options:

A.

Within the normal range of temperature and humidity

B.

High temperature and normal humidity

C.

Normal temperature and high humidity

D.

High temperature and high humidity

Buy Now
Questions 9

When allocating termination space for CAT 6 and optical fiber cables, it is recommended that additional space of up to ________ percent be considered for the routing of the cables and patch cords.

Options:

A.

Five

B.

Ten

C.

Twenty

D.

Thirty

Buy Now
Questions 10

Active video converters are required for what type of CATV distribution system?

Options:

A.

Video over balanced twisted-pair

B.

Trunk and tap

C.

Home run

D.

Video over optical fiber

Buy Now
Questions 11

An active video converter is used in what type of CATV cable distribution system?

Options:

A.

Trunk and tap

B.

Video over balance twisted-pair

C.

Video over optical fiber

D.

Home run

Buy Now
Questions 12

The headend has several modulators assigning frequencies for distribution to the CATV network. What distribution device should you use immediately at the headend to distribute the modulator's output signals to CATV system?

Options:

A.

Splitter

B.

Directional coupler

C.

Combiner

D.

Multiport tap

Buy Now
Questions 13

Which characteristic is an advantage of copper based media over optical fiber cable?

Options:

A.

Weight

B.

Corrosion resistance

C.

Ability to handle analog signals

D.

Susceptibility to EMI

E.

Very high data rates

Buy Now
Questions 14

Time division multiplexing (TDM) systems are designed to transport ________ between end point systems.

Options:

A.

Only analog signals

B.

Only digital signals

C.

A mix of both analog and digital signals

D.

Both analog and digital signals, but only one type at a time

Buy Now
Questions 15

Composite conductors, although not generally recommended, may be used in special circumstances because they provide all of the following advantages EXCEPT:

Options:

A.

Have good digital transmission characteristics

B.

Lightweight

C.

Inexpensive

D.

Easy to produce

E.

Easily embedded into other materials

Buy Now
Questions 16

You have discovered a common mode current on the metallic cable sheaths of your building riser cables. What is the MOST likely cause for you to investigate?

Options:

A.

Lack of cable protection

B.

Two separate and distinct ground references

C.

Improper secondary protection

D.

Improper physical protection of cable

E.

Improper placement and/or termination of cables

Buy Now
Questions 17

A common mode (CM) signal can be converted to a differential mode (DM) signal as a result of a(n):

Options:

A.

Unbalanced circuit

B.

Grounded circuit

C.

Poorly timed signal

D.

Improper dielectric material

Buy Now
Questions 18

What is the recommended MINIMUM separation of unshielded twisted-pair (UTP) cables from fluorescent light fixtures?

Options:

A.

77 mm (3 in)

B.

30 mm (5.12 in)

C.

203 mm (8 in)

D.

324 mm (12.75 in)

E.

483 mm (19 in)

Buy Now
Questions 19

Based on documentation contained within the Insulated Cable Engineers Association (ICEA) standard P32-382, Short Circuit Characteristics of Insulated Cable, a copper conductor is capable of safely carrying one ampere for ________ second(s) for every 42.25 circular mils.

Options:

A.

One

B.

Five

C.

Twelve

D.

Twenty

E.

Thirty

Buy Now
Questions 20

The MINIMUM dimensions of the telecommunications main grounding busbar is ________ and variable in length.

Options:

A.

4 mm (0.16 in) x 80 mm (3.15 in)

B.

6.3 mm (0.25 in) x 100 mm (4 in)

C.

8 mm (0.31 in) x 110 mm (4.33 in)

D.

10.5 mm (0.41 in) x 140 mm (5.51 in)

E.

12.75 mm (0.50 in) x 175 mm (6.89 in)

Buy Now
Questions 21

Electrical power cables are usually routed above aerial cable in order to:

Options:

A.

Provide aesthetics, as the power cables are bigger than the aerial cables

B.

Be a strength member in case a tree or something heavy falls on the lines

C.

Negate the need for protectors

D.

Intercept and divert direct power strikes

Buy Now
Questions 22

Which device supplies the radio signal into a DAS (distributive antenna system)?

Options:

A.

Amplifier

B.

Receiver

C.

Transmitter

D.

Transceiver

Buy Now
Questions 23

You are designing a 4.9 GHz microwave system that is using rectangular waveguide from the transceiver to the inside wall of the shelter and an antenna that is to be placed 200 ft up on a 250 ft tower. What type of medium will be best suited to connect the antenna to the transceiver?

Options:

A.

Circular wave guide

B.

Elliptical wave guide

C.

Hard line coaxial

D.

Rectangular wave guide

Buy Now
Questions 24

The propagation and path loss of radio signals in the target environment can be sampled using:

Options:

A.

Propagation software

B.

Radio power meters

C.

Directional antenna

D.

Mesh antennas

Buy Now
Questions 25

When balanced twisted-pair copper cabling, return loss is a measurement of the:

Options:

A.

Worst case difference in magnitude between the expected insertion loss and the actual measured insertion loss

B.

Reflection of signal power resulting from the insertion of a device in a transmission line (in dB)

C.

Signal coupling between any two pairs along the entire length of the cabling

D.

Loss in signal resulting from the insertion of a component, of link, or channel, between a transmitter and a receiver

E.

Time required for a signal to travel from one end of the transmission path to the other end

Buy Now
Questions 26

You have been asked to test and troubleshoot an installed base of cabling that is believed to be causing network problems. You are finding that there are high levels of return loss upon initial testing. What testing will best determine the reasons for these failures?

Options:

A.

Power meter

B.

Continuity testing

C.

Level II testing

D.

Time domain reflectometer (TDR)

Buy Now
Questions 27

Premises optical fiber links should be tested:

Options:

A.

In one direction at one corresponding wavelength

B.

In one direction at both corresponding wavelengths

C.

Bidirectionally at one corresponding wavelength

D.

Bidirectionally at both corresponding wavelengths

Buy Now
Questions 28

What type of optical fiber is used primarily for outside plant (OSP) applications?

Options:

A.

Tight-buffer

B.

Loose-tube

C.

Breakout style

D.

Duplex zip cord

E.

Ribbon

Buy Now
Questions 29

You must extend a video systems backbone coax cable that was recently installed. Which of the following coaxial cable types would provide the best performance for both analog and digital video?

Options:

A.

Series 6

B.

Series 11

C.

RG 16

D.

RG 59

E.

RG 62

Buy Now
Questions 30

The RJ-45 is now known as the 8P8C style connector, per the Telecommunications Industry Association (TIA) standard. What does the P and C stand for?

Options:

A.

Plug and connector

B.

Position and connector

C.

Position and contact

D.

Plug and contact

Buy Now
Questions 31

The MAXIMUM span length for an aerial entrance, from the last pole to the building, must NOT exceed:

Options:

A.

15.2 m (50 ft)

B.

30 m (100 ft)

C.

45.8 m (150 ft)

D.

61 m (200 ft)

E.

76 m (250 ft)

Buy Now
Questions 32

BICSI recommends that any trench ________ or more deep must be shored to prevent cave in.

Options:

A.

1.2 m (4 ft)

B.

1.5 m (5 ft)

C.

1.7 m (5.5 ft)

D.

1.83 m (6 ft)

E.

2.1 m (7 ft)

Buy Now
Questions 33

Buildings larger than ________ must contain a dedicated room for the termination of entrance facilities.

Options:

A.

5529 square m (60,000 square ft)

B.

7389 square m (80,000 square ft)

C.

9300 square m (100,000 square ft)

D.

11,160 square m (120,000 square ft)

E.

13,300 square m (140,000 square ft)

Buy Now
Questions 34

To accommodate telephone, data, CATV, security and multimedia, a MINIMUM of ________ strands of optical fiber auxiliary disconnect outlet (ADO) cable should be provided.

Options:

A.

Two

B.

Four

C.

Five

D.

Six

E.

Eight

Buy Now
Questions 35

Which service is NOT typical of Grade 1?

Options:

A.

Telephone

B.

Multimedia

C.

Data

D.

Television

Buy Now
Questions 36

You have just finished a design calling for 15 telecommunications outlets. You received word that the owner has increased his requirements by 40%. What size commercial DD (distribution device) is required to accommodate the increase?

Options:

A.

660 mm (26 in)

B.

1015 mm (40 in)

C.

1346 mm (53 in)

D.

1676 mm (66 in)

Buy Now
Questions 37

Perimeter raceway systems should be used primarily for:

Options:

A.

Underfloor pathway

B.

Apartments or hotels where molding is accessible in the work area

C.

Warehouses with minimal telecommunications services

D.

Small floor areas where the majority of telecommunication services will be along the walls

E.

Equipment rooms where cable tray is cost prohibitive

Buy Now
Questions 38

Which of the following is NOT an advantage of access floor systems?

Options:

A.

They have a low initial cost

B.

They are designed for high capacity

C.

They are aesthetically acceptable for office decor

D.

Cabling is easily accessible across the entire floor

E.

Changes can be made quickly with little occupant disruption

Buy Now
Questions 39

You are designing a horizontal distribution system that will have a zone box located 71.6 m (235 ft) away from the telecommunications room (TR). A 50 mm (2 in) conduit is designed from the TR to a pull box located 36.6 m (120 ft) away from the TR. A 1 1/2 inch conduit is designed from the pull box to the zone box located 35.1 m (115 ft) beyond the pull box. Assuming no conduit bends, and excluding the TR and zone box, what is the total number of pull boxes/pull points required in this horizontal conduit system between the telecommunications room (TR) and zone box?

Options:

A.

2

B.

3

C.

4

D.

5

Buy Now
Questions 40

IPv-4 addresses are ________ bits in length.

Options:

A.

16

B.

24

C.

32

D.

48

E.

64

Buy Now
Questions 41

The loop distance range in an "ethernet in the first mile" (EFM) design is:

Options:

A.

2 km (1.2 mi)

B.

4.8 km (3 mi)

C.

6.1 km (3.8 mi)

D.

9.7 km (6 mi)

E.

12 km (7.5 mi)

Buy Now
Questions 42

Which layer of the OSI model covers physical cable connections?

Options:

A.

Layer 1

B.

Layer 3

C.

Layer 5

D.

Layer 7

Buy Now
Questions 43

You are designing a cabling system for a chemical plant. What type of device is needed to prevent the spread of fire along the cable other than the barrier penetrations?

Options:

A.

Fire break

B.

Fire shield

C.

Fire stop

D.

Fire wall

Buy Now
Questions 44

A fire ________ is a contained area that is completely enclosed by fire resistant walls, floors, and ceilings.

Options:

A.

Rated system

B.

Stop system

C.

Wall

D.

Zone

Buy Now
Questions 45

Cementitious materials are ________ based materials.

Options:

A.

Dry powder

B.

Latex

C.

Solvent

D.

Sand

Buy Now
Questions 46

Within building automation hardware systems, there is a hierarchical system of micro processor based controllers. Which type of controller is used to provide limited port capacity for connection of sensors, support, and execution of DDC programs, and usually operates in stand alone mode?

Options:

A.

System level controller

B.

Field level controller

C.

Management level processor

D.

Protocol management system

E.

DDC manager

Buy Now
Questions 47

Which of the following protocols is referred to under ISO 16484-5?

Options:

A.

BACnet

B.

ARCnet

C.

European installation bus

D.

EMSLan

E.

LonMark

Buy Now
Questions 48

Within a commercial office building of 2300 sq m (25000 sq ft), how many building automation system (BAS) devices are required?

Options:

A.

50

B.

75

C.

100

D.

125

E.

150

Buy Now
Questions 49

Color codes for cross-connections fields have been used for many years. Which color is used to identify campus backbone?

Options:

A.

Brown

B.

Blue

C.

Green

D.

Purple

E.

White

Buy Now
Questions 50

Which class of the system applies when the premise only has a single equipment room (ER), and it is the only telecommunications space administered?

Options:

A.

Class 1

B.

Class 2

C.

Class 3

D.

Class 4

Buy Now
Questions 51

When labeling pathways, which one of the following guidelines should be met?

Options:

A.

Labeling should be affixed at the ends of each pathway.

B.

Pathways should not be labeled at regular intervals to avoid labeling removal during cable installation.

C.

Avoid marking conduits from the main equipment room (ER).

D.

Pathways do not need to have unique identifiers as they are only supporting cables.

E.

Only pathways containing fire/life/safety systems and electrical system should be labeled to prevent interference with other applications.

Buy Now
Questions 52

Rack mounted hardware is installed in two standard sized racks or cabinets. Those sizes are:

Options:

A.

482 mm (19 in) and 584 mm (23 in)

B.

482 mm (19 in) and 762 mm (30 in)

C.

610 mm (24 in) and 762 mm (30 in)

D.

762 mm (30 in) and 914 mm (36 in)

E.

482 mm (19 in) and 1020 mm (40 in)

Buy Now
Questions 53

When designing a backbone distribution system, you will need to include a telecommunications enclosure (TE). A TE can be defined as a:

Options:

A.

Splice point for copper cabling only

B.

Point where the backbone cabling interfaces to the horizontal cabling and may be utilized in place of a traditional Telecommunications Room (TR)

C.

Location for housing building cross-connect cabling only

D.

Location to house the splice transitioning from outdoor to indoor cabling only

E.

Facility to store slack copper and fiber cables

Buy Now
Questions 54

An installation crew is pulling an optical fiber cable into a riser. The cable has an outside diameter of 25 mm (1 in). As the cable is being pulled off the reel and through a pulley into the riser, you must verify that the minimum bend radius for the cable being pulled is observed. The pulley must be sized at a MINIMUM of:

Options:

A.

254 mm (10 in)

B.

381 mm (15 in)

C.

508 mm (20 in)

D.

635 mm (25 in)

E.

762 mm (30 in)

Buy Now
Exam Code: RCDD-002
Exam Name: BICSI Registered Communications Distribution Designer - RCDD
Last Update: May 20, 2024
Questions: 361

PDF + Testing Engine

$130

Testing Engine

$95

PDF (Q&A)

$80