Big Halloween Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: best70

H13-624_V5.5 HCIP-Storage V5.5 Questions and Answers

Questions 4

Cache policies and configurations are involved in storage-layer performance optimization of Huawei flash storage. Which of the following statements is false about the high and low watermarks of a cache?

Options:

A.

Generally, the low watermark for storing dirty data in the cache should not be too low. The recommended value is 20%.

B.

Generally, the high watermark of the cache should not be too high, and the difference between the high and low watermarks should not be too small.

C.

If the high watermark of the cache is too high, I/O fluctuation and latency increase will occur usually when the current I/O traffic bursts.

D.

If the high watermark of the cache is too high, the write performance will be affected. If the low watermark of the cache is too low, the read performance will be affected.

Buy Now
Questions 5

For device reliability purposes, during the quick Installation of OceanStor Pacific 9550, engineers need to connect power cables on the storage device supplied by two power modules to separate power distribution units (PDUs).

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 6

Assume a government office purchases several Huawei OceanStor Pacific series storage products. Which statement is false about the hardware and software deployment of the storage products?

Options:

A.

During software deployment, Device Manager must be used to initialize the network of nodes.

B.

During hardware deployment, SmartKit can be used to install OSs in batches.

C.

During software deployment, SmartKit can be used to configure clusters, such as disabling Link Layer Discovery Protocol (LLDP) for an OS and enabling the function of Baseboard Management Controller (BMC) mobile customization.

D.

SmartKit can be used to configure the BMC IP addresses, subnet masks/prefixes, gateways, and BMC host names, and to check the firmware, OS, and driver versions.

Buy Now
Questions 7

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

Options:

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Buy Now
Questions 8

The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.

Options:

Buy Now
Questions 9

Huawei scale-out storage provides file services using the distributed parallel client (DPC) to meet the requirements of high-performance computing (HPC) scenarios. Which of the following statements about the DPC is false?

Options:

A.

DPC provides high storage performance for HPC scenarios.

B.

DPC implements I/O-level load balancing, preventing service load forwarding between storage nodes.

C.

A single client can connect to multiple storage nodes, and the single-stream bandwidth is high.

D.

DPC does not support MPI-I/O. Therefore, DPC can provide better access performance for upper-layer services.

Buy Now
Questions 10

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Buy Now
Questions 11

Assume an Industry customer purchased a Huawel flash storage device for service deployment. After a fault occurs, an engineer needs to use the CLI to view bit error Information of front end host ports for troubleshooting. Which of the following commands cannot be used for this purpose?

Options:

A.

show coexist-forward-switch

B.

show controller io io_type=frontEnd controller_id=XX

C.

show port biLerror

D.

show host-port error

Buy Now
Questions 12

When delivering a Huawei flash storage project, an engineer introduced the SAN/NAS Integrated architecture to the customer. Which of the following statements Is false about the architecture?

Options:

A.

The protocol layer is responsible for protocol parsing and permission management. SAN and NAS are two sets of semantic logic. Therefore, different service entry components are used.

B.

The space management layer uses the active-active high reliability mode to provide reliable data protection capabilities based on actual service scenarios of customers.

C.

The software architecture consists of the following layers from top to bottom: protocol, data service, cache, file and block space management, and storage pool.

D.

At the protocol layer, NFS/CIFS supports direct TCP offload engine (DT06), while ISCSI does not.

Buy Now
Questions 13

A faulty storage hardware module needs to be replaced. Which of the following components can be replaced online?

Options:

A.

Controller enclosure backplane

B.

BBU

C.

Disk

D.

Interface module

Buy Now
Questions 14

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 15

A government customer has purchased several Huawei OceanStor Dorado 18000 series storage devices for service deployment, and an engineer needs to create storage pools on the storage system. However, before doing so, the engineer must configure LUNs and LUN groups, and create the mapping between the LUN groups and host groups.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 16

An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 17

The LUN active-active balancing feature of Huawei all flash storage Integrates the global load balancing.design. The front-end interface board evenly distributes I/Os to the target controller for load balancing.

Options:

Buy Now
Questions 18

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O&M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Buy Now
Questions 19

A government customer has purchased several Huawei scale-out storage devices, and an engineer wants to install the distributed parallel client (DPC). When creating DPC nodes, the engineer can manually add a node by entering the service IP address of the node.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 20

During routine O&M, an engineer finds that the system time of multiple Huawei flash storage devices Is Incorrect, and needs to correct the system time. Which of the following Is not a possible impact of changing the system time?

Options:

A.

If the new device time is later than the deadline for saving historical performance data, the system will no longer save historical performance data.

B.

Changing the device time will affect the life spans of disks and controllers, which may trigger alarms indicating that the hardware life span expires or hardware is aging.

C.

If the new system time is later than the user-defined password expiration date, the system may force the user to change the login password.

D.

If the new device time is later than the certificate validity period, the certificate will expire.

Buy Now
Questions 21

An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?

Options:

A.

SmartKit provides capabilities such as alarm reporting, file upload, and remote access.

B.

DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

C.

DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers’ O&M capabilities.

D.

The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

Buy Now
Questions 22

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

Options:

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Buy Now
Questions 23

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

Options:

A.

The min-queue-depth algorithm refers to the minimum queue depth algorithm. UltraPath is configured with this algorithm by default.

B.

Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

C.

The min-task algorithm is a round robin algorithm and can be used in scenarios where the service I/O models delivered by the host have little difference.

D.

The algorithms fall into three types: min-queue-depth, round-robin, and min-task.

Buy Now
Questions 24

When delivering a flash storage project, Huawei engineers introduced the multi-tenant feature of flash storage to the customer. This feature isolates service data. Although different tenants cannot access each other’s LUNs, they can access each other’s file system.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 25

When delivering Huawei all-flash projects, Huawei engineers introduced the HyperCDP feature of flash storage to customers. Which of the following statements are true about this feature?

Options:

A.

Copies created using HyperCDP can be used for data analysis and application testing.

B.

When an application server sends a request to write data to the source LUN after a HyperCDP snapshot is created, the storage system uses the copy-on-write (COW) technology to save the new data to a new location in the storage pool and directs the source LUN’s pointer to the new location.

C.

HyperCDP snapshots cannot be directly mapped to hosts. To read data from a HyperCDP snapshot due to actual service requirements, the administrator needs to share the file system with the host so that the host can read the source file system data at the point in time when the HyperCDP snapshot was created.

D.

HyperCDP is a high-density snapshot and requires the system to construct file system objects. Therefore, the system memory usage is high.

Buy Now
Questions 26

When the HyperReplication feature of Huawei scale-out storage is applied, If the properties of a consistency group are modified, the property modification will be synchronized to each pair in the consistency group. That is, the properties of the consistency group prevail.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 27

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Buy Now
Questions 28

SPC certification is a SAN performance test benchmark for third-party evaluation. Which of the following statements is true about SPC certification scenarios?

Options:

A.

SPC-2 applies to scenarios where random small I/Os are quickly responded.

B.

SPC-1 applies to scenarios of sequential large I/O access.

C.

SPC-2 applies to scenarios of sequential large I/O access.

D.

SPC-2 is used to test the SAN array performance in the OLPT, database, and email application scenarios.

Buy Now
Questions 29

In OceanStor Pacific series storage systems, if a node or disk is faulty, data reconstruction in the disk pool can be automatically performed after 15 minutes.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 30

An enterprise customer has purchased a Huawei OceanStor Pacific scale-out storage system for service configuration. An engineer wants to deploy the NFS file sharing service on the storage system and configure the HyperReplicatlon feature. Which of the following configuration operations are correct?

Options:

A.

When configuring HyperReplication, the engineer needs to configure the replication network route information on the primary storage system. The replication network route does not need to be configured on the secondary storage system.

B.

To use the NFSv4.0 protocol for share access, the engineer can run the "change service nfs_config nfsv40_status=enable account_name=?" command to enable the NFSv4.0 service.

C.

After a converged storage pool is created, the engineer needs to enable the file service. The HDFS or object service does not have to be enabled.

D.

When configuring HyperReplication, the engineer needs to create a remote replication pair on both the primary and secondary storage systems and then add a remote device.

Buy Now
Questions 31

An Internet customer has deployed a remote replication environment based on multiple flash storage devices. During actual service running, the customer discovers that there are multiple running statuses for a remote replication pair. Which of the following statements is true about the running status of a pair?

Options:

A.

After a pair is disconnected, if the pair is deleted from the primary or secondary site, which causes configuration inconsistency between the primary and secondary sites, the pair running status changes to "To be recovered."

B.

When the pair running status is "Split," the pair relationship between the primary and secondary LUNs is interrupted (not manually).

C.

When the pair running status is "Normal," data synchronization between the primary and secondary LUNs is complete.

D.

When the pair running status is "To be synchronized," the pair relationship between the primary and secondary LUNs must be manually disconnected to meet the service requirements of a single LUN.

Buy Now
Exam Code: H13-624_V5.5
Exam Name: HCIP-Storage V5.5
Last Update: Oct 30, 2025
Questions: 106

PDF + Testing Engine

$134.99

Testing Engine

$99.99

PDF (Q&A)

$84.99