Labour Day Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: netbudy65

Note! Huawei has retired the H13-622 Exam Contact us through Live Chat or email us for more information.

H13-622 Huawei Certified ICT Professional-Constructing Cloud Storage Solution Questions and Answers

Questions 4

The CIFS sharing of the OceanStor 9000 supports local user authentication and AD domain user authentication.

Options:

A.

True

B.

False

Buy Now
Questions 5

A customer has purchased a 4-node N8500 clustered NAS storage system. The enterprise-edition engine nodes have two CPUs, 10GE network ports, and 48 GB cache. The performance of an engine node reaches 700 MB/s. The back-end storage uses the S5600T, which is configured with 80 SAS disks divided into eight 9-disk RAID 5 groups. Each RAID group has one hot spare disk. The performance of each SAS disk in the 9-disk RAID 5 groups is 30 MB/s. According to the preceding information, what is the overall performance of the N8500 without considering other factors?

Options:

A.

700 MB/s

B.

2800 MB/s

C.

1920 MB/s

D.

2400 MB/s

Buy Now
Questions 6

Which of the following statements about the software installation of the OceanStor 9000 are correct? (Select two.)

Options:

A.

Before installing software, configure switches on the back-end storage network and the management network.

B.

The OceanStor Toolkit must be installed on all storage nodes.

C.

The OceanStor SystemReporter can be installed on any Windows server with qualified hardware and software.

D.

You must purchase a license for the OceanStor SystemReporter.

Buy Now
Questions 7

Which of the following statements about the file sharing protocols of the OceanStor 9000 are correct? (Select three)

Options:

A.

The OceanStor 9000 supports NFS and CIFS file sharing protocols.

B.

The OceanStor 9000 is compatible with various operating systems, allowing file resource sharing in a heterogeneous network environment.

C.

The sharing is by files.

D.

The sharing service supports automatic load balancing.

Buy Now
Questions 8

An OceanStor 9000 storage system is deployed using the OceanStor Toolkit. Which of the following statements about the settings of the OceanStor Toolkit configuration file are correct? (Select two)

Options:

A.

The cluster name can be set to9000cluster.

B.

If the InfoLink license has not been purchased, you may skip the InfoLink DNS configuration.

C.

The front-end network gateway will serve as the default gateway of all storage nodes after being configured.

D.

The data redundancy ratio is thedefault ratio of all directories on the OceanStor 9000.

Buy Now
Questions 9

The following figure shows the ports of two CE6850 switches when the OceanStor 9000 uses GE for the front-end network and 10GE for the back-end network. If the OceanStor 9000 uses C nodes, the ports in which area of the CE6850 switch must ports AO-0 and A0-1 on all the C nodes be connected to?

Options:

A.

A

B.

B

C.

C

D.

You do not need to connect C nodes to the CE6850 switch.

Buy Now
Questions 10

In the Huawei OceanStor 9000 system, which of the following functions or parameters will affect the InfoTier function?

Options:

A.

Signature function

B.

Notify function

C.

Access time tracking

Buy Now
Questions 11

Regarding the performance of the hard disk under various types of nodes of Huawei Oceanstor 9000, which one is the highest order from high to low?

Options:

A.

P25 Node SSD Hard Drive -> P25 Node SAS Hard Drive -> P12 SATA Hard Drive -> P36 Node SATA Hard Drive -> C36 SATA Hard Drive

B.

P25 Node SSD Hard Drive -> P25 Node SAS Hard Drive -> P12 SATA Hard Drive -> C36 SATA Hard Drive

C.

P25 Node SSD Hard Drive -> P25 Node SAS Hard Drive -> P36 Node SATA Hard Drive -> P12 SATA Hard Drive -> C36 SATA Hard Drive

D.

P25 Node SSD Hard Drive -> P25 Node SAS Hard Drive -> P36 Node SATA Hard Drive -> C36 SATA Hard Drive -> P12 SATA Hard Drive

Buy Now
Questions 12

Which of the following statements about the oceanstor 9000 InfoLocker feature is incorrect?

Options:

A.

WORM files can be modified and deleted

B.

The WORM clock can only be set once. After the setting is successful, the change is no longer allowed.

C.

When a directory is configured as a WORM root directory, all subdirectories, new directories, and new files of the directory are automatically obtained from the parent directory.

WORM attribute

D.

WORM protection submission method only supports automatic submission

Buy Now
Questions 13

What is the unit for CIFS/NFS/FTP sharing provided by Huawei OceanStor 9000?

Options:

A.

Directory

B.

Documentation

C.

User

D.

User group

Buy Now
Questions 14

When the Oceanstor 9000 (C30) shares files, the internal file copy function is added. When the client performs the following operations, it monitors the Huawei.

When I am an OceanStor 9000 client, I don't see data traffic? (multiple choice)

Options:

A.

When the client performs a copy and paste operation through the resource manager on Windows 7

B.

When the client performs a copy and paste operation through the resource manager on Windows 8

C.

When the client performs Windows 2003, when copying and pasting is performed through the resource manager

D.

When the client Suse10 is executed by the command to copy to the paste operation

Buy Now
Questions 15

Which of the following descriptions about the cache in Huawei OceanStor 9000 is wrong?

Options:

A.

The level 1 cache is the read cache of the storage node, and the location of the global cache is in the level 1 cache.

B.

The second level cache is used to cache the hotspot data of the node. Also cache hotspot data of other nodes in the same node

C.

The second level cache is composed of SSD disks. If there is no SSD disk in the node, there is no L2 cache.

D.

The report cache (NVDIMM) is primarily used as a write cache.

Buy Now
Questions 16

(Judging) When the OceanStor 9000 is deployed through the deployment tool, the IP address entered in the IP Address Range in the DHCP Configuration area is only

Temporarily used during the deployment process. After the deployment is successful, the IP address of each node is changed to the IP address planned in the configuration file.

Options:

A.

T

B.

F

Buy Now
Questions 17

The customer value of the Huawei OceanStor 9000 (C30) InfoEqualizer feature is reflected in: (multiple choice)

Options:

A.

Oceanstor 9000 can distribute requests to relatively idle nodes according to the current business load smart address of each node, thus enhancing customers.

B.

Oceanstor 9000 g automatically senses the fault and adjusts the service to other normal nodes, thus improving the reliability of client service access.

C.

This feature is a basic feature. You do not need to purchase a license to save costs.

D.

Allow the client to access the OceanStor 9000 using the domain name. The client operator does not need to know the Ip address for each specific access.

Management operations, which reduces management costs

Buy Now
Questions 18

Huawei OceanStor 9000 provides a single file system with a unified file system namespace. The following is about Oceanstor 9000.

Which one is incorrectly described in a namespace?

Options:

A.

The namespace is automatically created when the Oceanstor 9000 starts, and its name is consistent with the system name.

B.

The namespace is the root directory of the entire system and cannot be shared and accessed, as long as the subdirectories below it can be shared and accessed.

C.

A unified namespace provides users with a unified storage resource pool to achieve centralized management and allocation of storage space.

D.

Each file share directory is a subdirectory of the namespace

Buy Now
Questions 19

Which of the following options is incorrect for the Huawei OceanStor 9000 storage system metadata description?

Options:

A.

Oceanstor 9000 metadata is stored in a mirrored manner

B.

The metadata on each node is a complete, independent copy

C.

The purpose of image storage is to improve the security of metadata.

D.

Using mirroring does not provide system-to-metadata access rates.

Buy Now
Questions 20

(Judging) When planning the IP address of the back-end storage network of the OceanStor 9000 IB network deployment solution, you need to plan two back-ends for each node.

Storage IP address and 1 temporary IP address

Options:

A.

T

B.

F

Buy Now
Questions 21

What node types does Huawei OceanStor 9000 (V100R001C30) support?

Options:

A.

P12

B.

P25

C.

P36

D.

C36

E.

C72

Buy Now
Questions 22

The network connection is required before the big data system is initialized. The networking of Huawei OceanStor 9000 does not include ____.

Options:

A.

Front-end business network

B.

Backend storage network

C.

Management network

D.

Heartbeat network

Buy Now
Questions 23

What are the advantages of Huawei OceanStor 9000 clustered NAS technology over traditional NAS storage systems? Multiple selection

Options:

A.

Failover is fast, cluster single node failure does not affect business

B.

Multi-node cluster, load balancing, global cache, providing strong performance

C.

Engine cluster followed by SAN storage, SAN storage can use heterogeneous storage

D.

Scale-out engine architecture is extensible

Buy Now
Questions 24

(Judgement) Huawei OceanStor 9000 does not have performance bottlenecks due to the decentralized technology.

As the number of nodes increases, the storage capacity and computing power increase linearly, eventually providing users with linearly increasing bandwidth and concurrent numbers.

Options:

A.

True

B.

False

Buy Now
Questions 25

The network file sharing protocol supported by the NAS system mainly includes: (multiple choice)

Options:

A.

FAT32

B.

NTFS

C.

NFS

D.

CIFS

Buy Now
Questions 26

Which of the following is not in the Huawei OceanStor 9000?

Options:

A.

NIS authentication

B.

LDAP authentication

C.

Client IP address

D.

Local user authentication

Buy Now
Questions 27

The Erasure code redundancy technology used by the OceanStor 9000 supports higher reliability and more flexible redundancy strategies than traditional RAID algorithms.

Which of the following is the description of the principle of Erasure code N+M?

Options:

A.

When data is written, it is cut into N data blocks with the same size.

B.

Each of the N consecutive data blocks calculates M check blocks (M

C.

The system stores N+M data blocks in parallel on different hard disks.

D.

In Erasure Code storage mode, the system supports up to N hard disk failures.

Buy Now
Questions 28

(Multiple choices) Which node types does Huawei OceanStor 9000 (V100R001C30) support?

Options:

A.

P12

B.

P25

C.

P36

D.

C36

E.

C72

Buy Now
Questions 29

In the Huawei OceanStor 9000 InfoReplicator feature. Pair is a data replication relationship that describes the source and destination of data replication.

The next statement about Pair's state migration is incorrect (multiple choice)

Options:

A.

In the case of a Pair failure, its status includes recovery, failure, synchronization, splitting

B.

When the abnormal link is restored and the recovery policy is manual, the status of the Pair will be migrated to “Syncing”.

C.

When the InfoReplicator configuration is destroyed, the status of the Pair changes to "Failed".

Buy Now
Questions 30

Which of the following is the wrong description of the physical domain of the Oceanstor 9000?

Options:

A.

Physical domain is an effective means of isolating faults

B.

Some node failures cause a decrease in the reliability level of data on these nodes with other nodes in one physical domain.

C.

Oceanstor 9000 implements physical partitioning by means of node pooling and grading

D.

The administrator must add at least 2 storage nodes to a subdomain.

Buy Now
Questions 31

(Multiple choices) Which of the following storage units does the Huawei N8000 clustered NAS system use?

Options:

A.

S2200T

B.

S2600T

C.

S5500T

D.

S6800T

Buy Now
Questions 32

Single-choice) Which of the following is the correct sequence for powering up the Huawei OceanStor 9000 Big Data Storage System?

Options:

A.

Cabinet-->Switch-->KVM--->Node

B.

Cabinet --> KVM --> Switch ---> Node

C.

Cabinet --> Switch --> Node ---> KVM

D.

Cabinet --> Node --> KVM ---> Switch

Buy Now
Questions 33

The Oceanstor 9000 uses Erasure code technology to protect data. If a node has 7 nodes, and the customer wants disk utilization to

Less than 70%, the redundancy levels that can be used are: (multiple choice)

Options:

A.

6+1

B.

4+2

C.

6+4

D.

12+2:1

Buy Now
Questions 34

In the era of big data, you should also have big data thinking. Which of the following statements is incorrect?

Options:

A.

In the era of big data, the processing and analysis of data is no longer dependent on randomly sampled samples.

B.

In the era of big data, you should be keen on the accuracy of data.

C.

In the era of big data, the analysis of big data processing is more inclined to predict what will happen.

Buy Now
Questions 35

In the Huawei OceanStor 9000 system, if the client's access storage system node is unevenly distributed, the partition is re-adjusted.

After that, you need to uninstall the shared directory in each client and remount it with the assigned domain name.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 36

After the OceanStor 9000 is deployed, the deployment tool prompts “Connection is unsuccessful”. The possible reasons are: (multiple choice)

Options:

A.

The deployment tool and the deploy version do not match

B.

Unstable network connection between nodes

C.

The deploy process does not exist.

Buy Now
Questions 37

The Erasure code redundancy technology used by the Oceanstor 9000 supports higher reliability and more flexible redundancy than traditional RAID algorithms.

Slightly, the following describes the principle of Erasure code N+M, which one is wrong?

Options:

A.

When data is written, it is cut into N data blocks with the same size.

B.

Calculate M check blocks (M

C.

The system stores N+M song data blocks in parallel on different hard disks.

D.

In the Erasure code storage mode, the system supports up to N hard disk failures.

Buy Now
Questions 38

In which of the following situations occurs, does the Huawei OceanStor 9000 system not start load balancing?

Options:

A.

Add a node

B.

Add a hard disk

C.

The hard disk appears 3 times offline within 10 minutes

D.

Hard disk pre-failure

Buy Now
Questions 39

(Optional) When the following occurs, the Huawei OceanStor 9000 system does not start load balancing?

Options:

A.

Add a node

B.

Add a hard disk

C.

The hard disk appears 3 times offline within 10 minutes

D.

Hard disk pre-failure

Buy Now
Questions 40

An N8500 provides synchronous volume mirroring, which is similar to implementation of RAID 1 for the file system.

Options:

A.

True

B.

False

Buy Now
Questions 41

Which of the following components comprise the Storage Foundation of an N8500 clustered NASsystem? (Select two)

Options:

A.

VxVM

B.

VCS

C.

VxFS

D.

SFS

Buy Now
Questions 42

If homedir is enabled and a directory is specified, the OceanStor 9000 will automatically create a user directory for each user in the specified directory when local users or domain users access the OceanStor 9000 from clients for the first time. The users are authorized to read and write their own user directories. Other users, however, cannot access those user directories by default.

Options:

A.

True

B.

False

Buy Now
Questions 43

If an OceanStor 9000 storage system consists of four M nodes and uses 10GE for the back-end network, how many IP addresses must be planned for the back-end storage network segment?

Options:

A.

8

B.

12

C.

6

D.

10

Buy Now
Questions 44

Which of the following statements about the file system mirroring feature provided by an N8500 clustered NAS system are incorrect? (Select two)

Options:

A.

The N8500 supports a maximum of two mirrors for a single file system.

B.

Resources of different storage pools can be selected to implement file system mirroring.

C.

File system mirroring allows users to select three mirroring layout types.

D.

In the same service scenario, mirrored-stripe and striped-mirror provide the same data reliability and performance.

Buy Now
Questions 45

The flexible space of the OceanStor 9000 is attributed to the scale-out architecture, scalability from 3 to 288 nodes, and support for global namespace.

Options:

A.

True

B.

False

Buy Now
Questions 46

Which of the following device indicator states will not appear after an OceanStor storage system powers up and operates properly?

Options:

A.

The system Alarm indicators are off.

B.

The disk Running indicators are steady green.

C.

The disk Alarm/Location indicators are steady red.

D.

The system Running indicators on the GE switches are blinking green.

Buy Now
Questions 47

In performance optimization of the N8500 clustered NAS storage systems, the top command is runand the following output is displayed:

top - 01: 06: 48 up 1: 22, 1 user, load average: 0.06, 0.60, 0.48 Tasks: 29 total, 1 running, 28 sleeping, 0 stopped, 0 zombie Cpu(s): 0.3% us, 1.0% sy, 0.0% ni, 98.7% id, 0.0% wa, 0.0% hi, 0.0% si Mem: 191272k total, 173656k used, 17616k free, 22052k buffers Swap: 192772k total, 0k used, 192772k free, 123988k cached

Which of the following statements is incorrect?

Options:

A.

up 1:22 indicates the current system time.

B.

load average indicates the average length of taskqueues.

C.

0.3% us in Cpu(s) indicates the CPU occupation percentage of user space.

D.

17616k free in Mem indicates the total capacity of free memory.

Buy Now
Questions 48

Which of the following statements about the DST feature of an N8500 clustered NAS system are incorrect? (Select three)

Options:

A.

DST involves three tiers.

B.

Each tier can contain many volumes.

C.

All files are initially stored on tier 1.

D.

The location where metadata is stored cannot be manually specified.

Buy Now
Questions 49

Which of the following are possible challenges facing massive data management? (Select two.)

Options:

A.

How to implement quick data searches for higher retrieval efficiency

B.

How to ensure data authenticity and prevent data cheating

C.

How to implement PB-level storage of various data

D.

How to save storage resources by reducing the data amount

Buy Now
Questions 50

Which of the following is the correct N8500 configuration procedure?

Options:

A.

Go to the welcome page. > Confirm the networking. > Select a configuration file. > Configure storage units. > Configure the NA5 engine. > Configure the device location. > Complete the deployment.

B.

Confirm the networking. > Go to the welcome page. > Select a configuration file. > Configure storage units. > Configure the NAS engine. > Configure the device location. > Complete the deployment.

C.

Confirm the networking. > Go to the welcome page. > Configure storage units. > Select a configuration file. > Configure the NAS engine. > Configure the device location. > Complete the deployment.

D.

Confirm the networking. > Go to the welcome page. > Select a configuration file. > Configure the NAS engine. >Configure storage units. > Configure the device location. > Complete the deployment.

Buy Now
Questions 51

The HUAWEI OceanStor 9000 can be managed using web browsers. If an OceanStor 9000 storage system uses default settings, which of the following entered in the browser address box is correct?

Buy Now
Questions 52

An N8500 clustered NAS engine can be connected to a SAN storage array over a Fibre Channel network and a SAS network concurrently.

Options:

A.

True

B.

False

Buy Now
Questions 53

The N8500 clustered NAS storage system supports bonding of multiple service network ports.

Which of the following statements about bond4 and bond6 are correct? (Select three)

Options:

A.

The bond4 mode has unbalanced load issues in the "gatewayed" topology.

B.

The bond6mode allocates and adjusts loads based onthe workloads on the bond ports.

C.

The bond6 mode supports fault tolerance whereas the bond4 mode does not.

D.

The adaptive load balancing supported by the bond6 mode will definitely cause frequent switchovers among network adapters, increasing the systemoverhead.

Buy Now
Questions 54

The networking of an HUAWEI OceanStor 9000 big data storage system includes which of the following? (Selectthree)

Options:

A.

Front-end service network

B.

Back-end storage network

C.

Internal communication network

D.

IPMI management network

Buy Now
Questions 55

Hadoop is an open-source software framework for distributed processing of massive data. Hadoop has performance and cost advantages in terms of unstructured data processing.

Options:

A.

True

B.

False

Buy Now
Questions 56

In an OceanStor 9000 storage system, the calculate quota is set to 50 GB for user A to access the /dir directory. When the amount of data that user A writes exceeds 50 GB in the /dir directory, the system allows user A to continue to write data in the /dir directory.

Options:

A.

True

B.

False

Buy Now
Questions 57

Which of the following statements about the system services of the OceanStor 9000 are correct? (Select two)

Options:

A.

The MDS service manages the metadata of a file system.

B.

The DS service stores file data but not metadata on the storage system.

C.

The CMS service manages physical nodes in a cluster.

D.

In an OceanStor 9000 storage system, some nodes provide the MDS service and some nodes provide the DS service.

Buy Now
Questions 58

If the service disk in slot 35 on a C node of the OceanStor 9000 is faulty, you are supposed to find this disk at the front panel of the C node and then replace it.

Options:

A.

True

B.

False

Buy Now
Questions 59

Which of the following statements about the characteristics of the file system snapshot feature provided by an N8500 clustered NAS system are incorrect? (Select two.)

Options:

A.

A snapshot and the file system each use independent storage space to ensure data reliability.

B.

A file system snapshot is a view identical with the file system.

C.

File system snapshots are readable, writable, and independent of the file system.

D.

You can create multiple snapshots for a file system. However, you cannot create a snapshot for an existing snapshot.

Buy Now
Questions 60

In performance optimization of the N8500 clustered NAS storage systems, which of the following issues must the maintenance personnel be aware of concerning LUNs and controllers? (Select three.)

Options:

A.

Create only one LUN for each RAID group.

B.

Set LUNs to forcible write back without mirroring.

C.

Ensure that the owning controller and the working controller of a LUN are the same.

D.

Disks that compose a file system are evenly distributed on controllers.

Buy Now
Exam Code: H13-622
Exam Name: Huawei Certified ICT Professional-Constructing Cloud Storage Solution
Last Update: Apr 14, 2023
Questions: 405