Summer Certification Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: best70

D-PE-OE-01 Dell PowerEdge Operate v2 Exam Questions and Answers

Questions 4

An engineer needs to install an OS that is not supported by the Lifecycle Controller on a Dell PowerEdge server. Since the OS Deployment menu cannot be used, the engineer plans to proceed with a manual installation. Which two factors should be considered in this situation?

Options:

A.

Appropriate drivers based on storage configuration must be applied.

B.

Required drivers are manually managed during installation.

C.

Hardware compatibility with the OS must be verified before installation.

D.

Firmware and driver version compatibility is checked after installation.

Buy Now
Questions 5

A company operates a Dell PowerEdge server configured with a RAID 10 virtual disk that hosts critical databases services. Monitoring tools indicate that the virtual disk usage has reached 95% of total capacity. The server provides 24/7 mission-critical services, so downtime must be minimized or completely avoided. Currently, the server has only one empty drive bay remaining. What should the operations team consider first to safely plan the expansion of the RAID 10 virtual disk?

Options:

A.

Check the RAID controller's capabilities, available drive bays, and whether expansion is supported.

B.

Replace the RAID controller with the latest model to guarantee maximum performance, then add the new disk.

C.

Add the new disk, trigger a rebuild of the RAID, and wait until the rebuild is complete before using the expanded capacity.

D.

Add the new disk and immediately perform Online Capacity Expansion through iDRAC.

Buy Now
Questions 6

A technician receives a new server with five drives. They need to configure the drives based on the following requirements received from the administrator:

• Drive 0 as a single disk with no RAID

• Drives 1-3 as a RAID 5 with drive 4 as a hot spare just for this newly created RAID 5

The administrator plans to add more disks as separate RAID arrays at a later date but only wants drive 4 to be available for this first RAID 5 set.

How should the technician configure the drives?

Options:

A.

Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

B.

Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare

C.

Set drive 0 to Ready; set drives 1-3 as RAID 5; set drive 4 as a Dedicated Hot Spare

D.

Set drive 0 to Non-Raid; set drives 1-3 as RAID 5; set drive 4 as a Global Hot Spare

Buy Now
Questions 7

You are in a dark site with a PowerEdge server that shows an amber light. iDRAC Is not configured for network access but the OS is installed and has RACADM for access to the iDRAC card. What RACADM command can be used to help identify the cause of the amber light?

Options:

A.

getsel

B.

getssninfo

C.

getsysinfo

D.

get led

Buy Now
Questions 8

You are asked to perform a quick health check across multiple NVIDIA GPUs in a cluster without impacting running workloads. Which DCGM diagnostic level should be used?

Options:

A.

Level 1

B.

Level 2

C.

Level 3

D.

Level 4

Buy Now
Questions 9

A Dell PowerEdge server is experiencing intermittent hardware alerts, and the operating system is occasionally unresponsive. An administrator needs to diagnose and troubleshoot the hardware issue efficiently. Which three tools can be used to troubleshoot hardware issues on a Dell PowerEdge server?

Options:

A.

Operating system application logs

B.

LiveOptics

C.

OME

D.

iDRAC

E.

Lifecycle Controller diagnostics

Buy Now
Questions 10

A PowerEdge server is running critical production workloads and has passed all validation and compliance checks. The security team requires that no unauthorized or accidental changes be made to the system configuration during the production phase. Later, the administrator attempts to update the BIOS remotely using iDRAC but the operation fails without applying any changes. Which is the most likely reason for this behavior?

Options:

A.

TPM is blocking the firmware operation

B.

System Lockdown Mode is enabled

C.

Secure Boot is preventing the BIOS update

D.

The RAID controller is in a degraded state

Buy Now
Questions 11

A system administrator must update the virtual console security settings on their PowerEdge server to comply with company standards. The company requires strong encryption and secure access policies. Which setting meets these requirements?

Options:

A.

Use a strong password

B.

Disable SSL encryption for faster performance

C.

Configure an acceptable timeout value

D.

Set SSL encryption to 256-bit or higher

Buy Now
Questions 12

A PowerEdge server unexpectedly rebooted, and the SEL did not provide enough information to determine the cause. Upon investigation, the engineer noticed that the Last Crash Screen feature was disabled and recommended enabling it. Which primary gap does enabling the Last Crash Screen address?

Options:

A.

The system may lose the final crash state before logs are written.

B.

OS-level crash dump data may be incomplete when writes fail.

C.

Crash during POST may cause firmware messages to be lost.

D.

Sensor activity may not be captured when a crash occurs suddenly.

Buy Now
Questions 13

A Dell PowerEdge server reports intermittent hardware alerts and occasional system instability. An administrator needs to Identify and resolve the underlying hardware Issue with minimal disruption to services. Which action should the administrator take first to troubleshoot the hardware problem?

Options:

A.

Use iDRAC to review hardware health status and the SEL

B.

Disable monitoring alerts to prevent false warnings

C.

Reinstall the operating system to eliminate software-related causes

D.

Replace multiple hardware components simultaneously

Buy Now
Questions 14

A Dell PowerEdge R750 shows a sudden reduction in usable capacity on a RAID 6 virtual disk after replacing a failed drive with a larger one. The OS and iDRAC both report the VD as “Ready’" and “Optimal" but usable capacity remains unchanged. What is the cause of this behavior?

Options:

A.

The drive was added as a dedicated hot spare instead of a member disk

B.

The virtual disk remains limited by the smallest disk

C.

The rebuild failed and the virtual disk is using reduced capacity mode

D.

The virtual disk automatically expanded but the OS has not refreshed

Buy Now
Questions 15

You are replacing a network card in a Dell server. The new card has a firmware version lower than the existing part. The Lifecycle Controller Is set to Allow Version Upgrade only under the Part Firmware Update setting. What will happen to the firmware after replacing the card?

Options:

A.

Forces downgrade of existing firmware

B.

Updates the network card firmware

C.

Prevents all firmware updates

Buy Now
Exam Code: D-PE-OE-01
Exam Name: Dell PowerEdge Operate v2 Exam
Last Update: Jul 16, 2026
Questions: 50

PDF + Testing Engine

$134.99

Testing Engine

$99.99

PDF (Q&A)

$84.99