CDCP Certified Data Centre Professional (CDCP) Questions and Answers

Questions 4

Does shielded twisted pair network cabling provide protection against EMF from power cables?

Options:

A.

Yes, but only if the power cable is placed in a tre-foil cable arrangement.

B.

Yes, as the shielding for twisted pair network cabling is specifically design for low frequency EMF protection.

C.

No, the shielding is designed for alien cross-talk between network cables, it provides no or little protection against low frequency EMF.

D.

No, the shielding for twisted pair network cabling is for physical protection against vandalism and accidental cutting of the cable.

Buy Now
Questions 5

Looking from within the Computer room, what should the door-swing (opening) direction be?

Options:

A.

Outwards, code permitted

B.

Instead of swinging doors, sliding doors are preferred

C.

Depends on the type of Computer room

D.

Inwards, code permitted

Buy Now
Questions 6

What is the main risk for a data centre when the water supply fails?

Options:

A.

Failure to the water supply could result in IT failure and/or denial of access to operate.

B.

Failure to the water supply could result in DX cooling systems to fail.

C.

Failure to the water supply could cause issues for the cooling of back-up generators.

D.

Failure to the water supply could result in sudden changes of the relative humidity in the Computer room.

Buy Now
Questions 7

Which type of copper wire is used for grounding the racks to the SRG?

Options:

A.

Thin copper cable to keep the cost low for grounding.

B.

Thick copper cable to create better grounding.

C.

Braided copper wire or flat copper strip.

D.

Copper cable with plastic insulation (isolation).

Buy Now
Questions 8

When having two non-synchronized power sources, the ATS / STS need to be of the type:

Options:

A.

Break before make.

B.

Make before break.

C.

Both make before break or break before make can be used.

D.

Both an ATS and STS can never handle two non-synchronized sources.

Buy Now
Questions 9

Which of statements below is true?

Options:

A.

Single-mode cabling can use both LED and laser as a light source.

B.

Single-mode cabling is more expensive than multi-mode cabling.

C.

Multi-mode cabling can cross longer distances.

D.

Multi-mode cabling is more expensive than single-mode cabling.

Buy Now
Questions 10

Which formula is correct?

Options:

A.

Watt = VoIt-Ampere / Power Factor

B.

Watt = Volt-Ampere * Power Factor

C.

Power Factor = Volt Ampere ' Watt

D.

Volt-Ampere = Watt * Power Factor

Buy Now
Questions 11

The three elements of the fire triangle are,and. (Choose three.)

Options:

A.

Oxygen

B.

Earth

C.

Heat

D.

Water

E.

Fuel

Buy Now
Questions 12

is the arithmetic mean of time between the failing and the subsequent running of the system in a particular time period.

Options:

A.

MTBF

B.

MCBF

C.

MLBF

D.

MTTR

Buy Now
Questions 13

When dealing with glass door racks, cool air is injected into the rack from:

Options:

A.

The rear door in a downflow direction.

B.

The front door in a downflow direction.

C.

The top of the rack through the fans and vents mounted inside the rack.

D.

The bottom of the rack.

Buy Now
Questions 14

What is the best practice for cutting holes in the raised floor tile?

Options:

A.

Anywhere as data centre tiles are designed to allow cut-outs anywhere.

B.

Draw a cross on the tile and when making a cut-out do not touch a line and avoid the corners.

C.

Draw a line in the middle of the tile and never touch the line when making the cut.

D.

Cut the tiles at the corner so the pedestals can be used as a vertical cable manager.

Buy Now
Questions 15

Which one of the following is an AC Power Quality Anomaly?

Options:

A.

Signal Distortion

B.

Waveform Distortion

C.

Backup Condition

D.

Attenuation

Buy Now
Questions 16

What should be a consideration when having casters (rollers/wheels) or feet under the rack?

Options:

A.

The casters and feet should be larger to avoid a too heavy point load on the floor tile.

B.

Skirts at the bottom of the rack to avoid air flow between the hot and cold aisles.

C.

Casters and feet should be of a soft material, for example rubber, to avoid damage to the raised floor tile.

D.

Casters and feet should not be locked to ensure the racks are still able to be moved to another position.

Buy Now
Questions 17

systems are designed specifically to protect the structure of a building.

Options:

A.

Pro-inert

B.

Inergen

C.

Water sprinkler

D.

Total Flooding

Buy Now
Questions 18

Can Electro Magnetic Fields (EMF) cause data centre failures?

Options:

A.

Yes, high levels of EMF can cause data centre failures.

B.

No, only power issues will cause data centre failures.

C.

No, only cooling issues will cause data centre failures.

D.

Yes, but only EMF caused by lightning strikes.

Buy Now
Questions 19

Which type of Humidifier rapidly vibrates waster to create a fog or mist?

Options:

A.

Infrared Humidifier

B.

Water Canister Humidifier

C.

Steam Canister Humidifier

D.

Ultrasonic Humidifier

Buy Now
Questions 20

Which is the most damaging type of floor load?

Options:

A.

Concentrated Load / Point Load (CP/ PL)

B.

Uniformly Distributed Load (UDL)

C.

Rolling Load (RL)

D.

All loads are equally damaging to raised floor tiles

Buy Now
Questions 21

Which source is used in fiber cable to transmit data?

Options:

A.

Signals

B.

Electric

C.

Light

D.

Pulse

Buy Now
Questions 22

Which Class of Fires involves ordinary combustible materials such as paper, wood and cloth?

Options:

A.

Class A

B.

Class B

C.

Class D

D.

Class K

Buy Now
Questions 23

is the degree to which a system or component is operational and accessibility when required for use.

Options:

A.

Scalability

B.

Agility

C.

Reliability

D.

Availability

Buy Now
Questions 24

Mean time between failures is best considered a measure of:

Options:

A.

Size

B.

Cost

C.

Duration

D.

Reliability

Buy Now
Questions 25

Which Class of Fires involves energized electrical equipment?

Options:

A.

Class A

B.

Class B

C.

Class C

D.

Class K

Buy Now
Questions 26

Which formula can be used to define risk?

Options:

A.

Risk = Time * Quality

B.

Risk = Security * Criminality

C.

Risk = Impact * Probability

D.

Risk = Probability * Cost

Buy Now