The occupant load of a building, or portion thereof, may be increased beyond the code's calculated minimum for the Group classification of the building, provided that all other requirements of the code are also met based on the modified number, and the occupant load does not exceed one occupant per ___ sq. ft.
Existing elevators in a four-story office building which are intended for use by emergency personnel for fire-fighting or rescue purposes must comply with which of the following standards?
Conditions that may exist and warrant a modification include all of the following except where the:
Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.
The minimum allowable distance to a public traffic route for storage of 1,750 lb. of Class 1.3 explosives is ___ ft.
What fire-resistance rating is required for interior nonbearing wall and partitions in Type IV construction?
Newly upholstered furniture may be required to resist ignition by cigarettes in common areas in which of the following nonsprinklered occupancies?
Given: A nonsprinklered building constructed with protected noncombustible material has a fire-resistive rating of a minimum of 1 hour. What is the most protective type of construction, from the choices below, that meets these parameters?
Churches, schools, apartment dwellings, and mercantile structures are commonly built using what type of construction?
The maximum travel distance permitted in a one-story, Group F-2 building equipped with automatic sprinklers and automatic smoke and heat roof vents is __ ft.
Keys necessary for the unlocking of exit doors must be individually identifiable by both sight and touch in which of the following occupancies?
A "control area" is defined by the fire code as a building or portion of a building within which the exempted amounts of ___ are allowed to be stored, dispensed, used, or handled.
Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.
All new building construction must have installed an approved water supply for fire protection which provides a minimum of:
Given: Scheduling inspections should be done to obtain a high level of efficiency. When scheduling inspections at multiple occupancies on the same day, the inspector should:
Battery-charging areas for industrial trucks shall be protected with portable fire extinguishers which have a minimum rating of:
Horizontal exits shall not comprise more than ___ of the required exits from any floor area in a Group I-2 occupancy.
The interior finish of walls and a ceiling in an atrium may not be less than __ Class
At each grinding, buffing, or wire brushing operation on magnesium, other than the rough finishing of casting, dust must be collected by means of suitable hoods or enclosures connected to a:
The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.
When investigating a complaint of a violation within an occupied public area, the fire inspector: